Troubleshooting

ly

If you are experiencing any issues with your applicator we are more than happy to help you locate the problem. This page includes some of the common mishaps we run into - if this is not the information you are looking for please call us at 320-252-8999.

Electrical - Verify 12 Volt DC System


Pumping/Priming - Conventional




1.) Verify product in the tank and that the valves are open

2.) Verify all gaskets are in place, good condition and seated properly
                   - Filter
                   - Inlet connection (from tank) ; Swivel or Cam-lock connection

3.) Check for loose fittings and hose clamps

4.) Inspect for cracked fittings
                  - Pump housing
                  - Filter housing

5.) Inspect for plugs on output of system

6.) Replace valve kit

Pumping/Priming - Low Volume (Dohrect Enject)




1.) Verify product in the tank and valve is open and the proper orientation

2.) Check for loose fittings
          - Luer “box” fittings (DE-1000)
          - Pumping tube connection - verify a “click” (DE-1008.5)

3.) Inspect for cracked fittings
          -Thru-wall fittings (DE-1008.5)

4.) Inspect for any plugging
         - Filter on inside of cooler
         - Valve assembly on cooler
         - Flowmeter & connections

5.) Replace pumping tube (suggested annually)

What to
try…

Problem:
The motor doesn’t run

Is the switch/controller turned on?

Option 1:

Verify whether or not the red light comes on.

Option 2:

Bypass the switch/controller; simply take it out of the equation.

The connections that the controller plugs into on either end are a mated pair.  

If no:

1.) Bad connection at power supply: clean and tighten connections

2.) Bad motor: replace or send in for repair (if applicable)

What to
try…

If not - check the connections at the power supply

RED (+) and BLACK (-)

Does the motor run now?

If yes:

Bad switch/controller - Replace or send in for repair